EPA and USDA · Training guide
Veterinary Serial Release
Write the release summary for a serial of a USDA-licensed veterinary biologic: each 9 CFR 113 test checked against the Outline of Production, potency margin, dating, retests and sampling, ready for APHIS Form 2008.
Open the tool at https://app.cmcfy.com/app/veterinary-serial-release.html. This guide is also online at https://cmcfy.com/guides/veterinary-serial-release.html
1. What this module does
You give the serial, its dates, the release and expiry potency minimums and the samples taken, then list each test with its criterion and result.
The tool evaluates each result, flags failures and results it cannot evaluate, retests with no reason, a release minimum that does not cover the dating period, an expiration date beyond the approved dating and too few samples.
What you get
- A Word or PDF file: serial release summary with the APHIS Form 2008 data.
2. Before you start
Have these ready. You can still start with the example data and replace it piece by piece.
- The Outline of Production test list and criteria.
- The serial test results.
- The approved dating period.
3. Step by step with the example
Open the tool at app.cmcfy.com/app/veterinary-serial-release.html. The example is loaded when the page opens, so every panel already has realistic data. Follow the steps to see how it works, then replace the example with your own data.
Describe the serial
Serial number, size, manufacture and expiration dates, the potency minimums and the samples taken.

Enter the tests
One row per test with the 9 CFR section, the criterion and the result. Mark retests and give the reason.
Read the result
The headline says whether the serial meets the release requirements.

Each test with its outcome. Resolve alerts and download
A failed test or an expiration date beyond the approved dating is critical. Then preview and download.

4. Field reference
Every input in the tool, panel by panel. Tables accept rows pasted straight from Excel, comma-separated text, or a loaded file; check the columns after loading a file. Fields marked “when it applies” appear only for the choices that need them.
1 · Serial
| Field | What to enter |
|---|---|
| Product | Type it in. |
| Product code and licence | Type it in. |
| Serial number | Type it in. |
| Serial size (doses) | Type a number. |
| Date of manufacture | Type it in. |
| Expiration date | Type it in. |
| Dating period approved in the Outline (months) | Type a number. |
| Release potency minimum (relative potency) | Type a number. |
| Expiry potency minimum (relative potency) | Type a number. |
| Final container samples taken | Type a number. |
| Samples required by the Outline (9 CFR 113.3) | Type a number. |
2 · Tests
One row per test in the Outline of Production. Retest: yes when this is a repeat of an earlier test, with the reason.
| Field | What to enter |
|---|---|
| Serial tests | Write criteria as "≥ 1.2", "≤ 0.074%", "No growth" or "Satisfactory". A table. Columns: Test | 9 CFR | Criterion | Result | Retest (yes/no) | Retest reason. Paste rows from Excel, type comma-separated rows, or press Load file (Excel, CSV, Word, PDF or a scan). |
5. Checks and alerts
Calculations and pass/fail outcomes always come from fixed rules, never from AI. The tool checks:
- Each test against its criterion.
- Potency margin and dating.
- Retests and sampling.
How to resolve alerts
- Critical alerts block the download and must be fixed in the data. A failing result can instead be linked to an investigation: type the investigation reference and outcome and press Record.
- Major alerts block the download until you fix them or type a justification and press Accept justification.
- Minor alerts do not block anything. They are listed in the documents so the reviewer sees them.
- Some alerts have an Apply fix button that makes the change for you. Reopen undoes a justification.
Narratives
This module writes: Release conclusion. Each narrative is written by fixed rules from your data. You can edit it in the box. Rewrite with AI (where your plan includes AI) rewrites it in regulatory style; every number in the text is checked against your data, and a number that does not match is flagged under the box and blocks the download until you correct it. Reset to rule-based text brings back the original.
6. Preview, gap review and download
- Press Preview next to a section, or Preview and download all. The document opens in a preview window, exactly as the Word file will read.
- The left side lists the review, run on your device: gaps in the data (missing values, open alerts), gaps in the report (missing content the guidance expects, placeholders such as [site] or TBD left in the text) and, if you load the approved protocol under Compare with the protocol, differences from the protocol (requirements, criteria, batches or time points it plans that the report does not show).
- Click a finding to jump to the place in the preview. Fix it in the tool, then preview again.
- Optional AI review: a second read for contradictions, claims without data and vague wording. The report text is sent to Claude only when you press it, and only where your plan includes AI. Check every AI finding; AI can be wrong.
- Press Download Word (.docx) or Download PDF. With several documents open, All as Word (.zip) and All as PDF (.zip) download the set. The download buttons stay disabled while a blocking alert is open; the preview still works.
Documents this module produces
| Section | Document |
|---|---|
| CVB | Serial release summary (APHIS Form 2008 data) |
Use Save project to keep your work as a file on your computer, and Open project to continue later. Start blank clears every field; Load example brings the example back. Nothing is stored on CMCfy servers.
7. US and EU submissions
US only: 9 CFR 113 and APHIS Form 2008.
8. Working with other modules
- The tests and criteria come from the Outline of Production filed with the Veterinary Biologics Licence.
9. Common pitfalls
- Retesting a failed serial without an inconclusive first test.
- A release potency minimum equal to the expiry minimum.
10. Practice exercises
Each exercise starts from the example (press Load example to reset). We run these on every update of this guide, so the result you see should match.
Use the valid retest result
The first BVDV-1 potency test was inconclusive (reference out of range); enter the retest result 1.32.
Expected resultThe serial meets the release requirements.